can dump
Passively captures CAN frames from a SocketCAN interface and reports traffic statistics, the most active IDs, and any security-relevant IDs.
Status
| Result | Meaning |
|---|---|
pass | Capture completed (even if no frames were received) |
fail | Interface could not be opened |
Severity classification
| Severity | Condition |
|---|---|
| High | OBD-II diagnostic IDs present (0x7DF, 0x7E0-0x7EF) |
| Medium | CANopen SDO/NMT/PDO IDs present |
| Low | CAN error frames detected |
| Info | Traffic summary, top IDs, no traffic, or read error |
Usage
iottack can dump [OPTIONS]
Options
| Flag | Short | Default | Description |
|---|---|---|---|
--iface <IFACE> | -i | can0 | SocketCAN interface name |
--duration <SECS> | -d | 10 | Capture duration in seconds |
--max-frames <N> | - | 10000 | Stop early after capturing this many frames |
--output <FILE> | -o | - | Save result to a file |
--format <FORMAT> | -f | text | text or json |
--verbose | -v | - | Increase log verbosity |
Description
The plugin opens the specified SocketCAN interface in read-only mode (no frames
are transmitted) and collects frames for the configured duration or until
--max-frames is reached.
After capture it reports:
- Traffic summary: total frame count, unique ID count, frame rate, error frame count.
- Top 10 IDs by volume: the most active IDs with their frame count, DLC and last observed payload.
- Notable IDs: any ID matching a known protocol range (CANopen, OBD-II) is reported as a separate finding at an elevated severity.
Error frames (bus-off, bit errors, CRC errors) are counted separately and reported at Low severity because they may indicate a bit-rate mismatch, wiring fault or active fault injection.
ID classification
| ID range | Protocol | Severity |
|---|---|---|
| 0x000 | CANopen NMT master | Medium |
| 0x001 - 0x07F | CANopen SYNC/timestamp | Medium |
| 0x080 - 0x0FF | CANopen EMCY (emergency) | Medium |
| 0x100 - 0x4FF | CANopen PDO | Medium |
| 0x580 - 0x5FF | CANopen SDO server response | Medium |
| 0x600 - 0x67F | CANopen SDO client request | Medium |
| 0x700 - 0x77F | CANopen NMT heartbeat | Medium |
| 0x7DF | OBD-II functional broadcast | High |
| 0x7E0 - 0x7E7 | OBD-II physical request to ECU | High |
| 0x7E8 - 0x7EF | OBD-II response from ECU | High |
Examples
Default 10-second capture on can0:
iottack can dump
Longer capture on a custom interface:
iottack can dump --iface vcan0 --duration 60
Save to JSON for further processing:
iottack can dump --duration 30 --format json --output can-dump.json
Example output
Plugin name: can/dump
Execution time: 10.01 s
Status: pass
[INFO] can0: 4823 frame(s), 7 unique ID(s) in 10.0s (482.1 fps)
Data frames: 4823
Frame rate: 482.1/s
Unique IDs: 7
Error frames: 0
[INFO] Top 7 CAN ID(s) by volume on can0
181h count=1621 dlc=8 last=[00 00 00 00 E8 03 00 00]
280h count=1203 dlc=8 last=[7F 00 00 00 FF 1F 00 00]
380h count=802 dlc=8 last=[00 00 00 00 00 00 00 00]
701h count=401 dlc=1 last=[05]
702h count=401 dlc=1 last=[05]
7DFh count=200 dlc=3 last=[02 01 00]
7E8h count=195 dlc=6 last=[06 41 00 BE 1F A8 13]
[MEDIUM] Notable CAN ID 701h: CANopen: NMT heartbeat/node guarding
ID 701h seen 401 time(s). Last frame: dlc=1 data=[05]
[MEDIUM] Notable CAN ID 702h: CANopen: NMT heartbeat/node guarding
ID 702h seen 401 time(s). Last frame: dlc=1 data=[05]
[HIGH] Notable CAN ID 7DFh: OBD-II: diagnostic broadcast - exposes vehicle diagnostics (ISO 15765-4)
ID 7DFh seen 200 time(s). Last frame: dlc=3 data=[02 01 00]
[HIGH] Notable CAN ID 7E8h: OBD-II: diagnostic response from ECU (ISO 15765-4)
ID 7E8h seen 195 time(s). Last frame: dlc=6 data=[06 41 00 BE 1F A8 13]
Troubleshooting
Cannot open interface
Verify the interface exists and is up:
ip link show type can
sudo ip link set can0 up type can bitrate 500000
No frames received
- Confirm the target bus is powered and has active traffic.
- Check the bit rate matches the bus: a mismatch causes all frames to be discarded at the hardware level with no error returned to userspace.
- Run
ip -details link show can0to view the current bitrate and bus state.
Error frames