modbus read-registers

Reads a contiguous block of 16-bit registers from a Modbus device. Supports both holding registers (FC03) and input registers (FC04).

Holding registers are general-purpose read/write 16-bit values typically used for setpoints, configuration, and counters. Input registers are read-only 16-bit values typically representing analog measurements and sensor readings.

The finding reports all register values in hex and decimal and counts how many hold non-zero values.

Status

ResultMeaning
passRegisters read successfully
failRead failed or connection error

Severity classification

SeverityCondition
HighRegisters returned (unauthenticated read succeeded)
InfoRead failed or connection failed

Usage

iottack modbus read-registers --host <HOST> [OPTIONS]
iottack modbus read-registers --serial <DEVICE> [OPTIONS]

Options

FlagShortDefaultDescription
--host <HOST>-H(required or –serial)Target hostname or IP for Modbus/TCP
--tcp-port <PORT>-502Modbus/TCP port
--serial <DEVICE>-s(required or –host)Serial device for Modbus RTU (e.g., /dev/ttyUSB0)
--baud <BAUD>-9600Baud rate for RTU serial
--unit <ID>-u1Modbus unit/slave ID (1-247)
--timeout-ms <MS>-t3000Timeout in milliseconds
--address <ADDR>-a0Starting register address (0-65535)
--count <N>-c10Number of registers to read (max. 125)
--register-type <TYPE>-Tholdingholding (FC03) or input (FC04)
--output <FILE>-o-Save result to a file
--format <FORMAT>-ftexttext or json
--verbose-v-Increase log verbosity

--count is capped at 125, the Modbus protocol maximum per request.

Examples

Read the first 10 holding registers:

iottack modbus read-registers --host 192.168.1.100

Read 20 input registers starting at address 100:

iottack modbus read-registers --host 192.168.1.100 \
  --register-type input --address 100 --count 20

Read over RTU serial, unit ID 3:

iottack modbus read-registers --serial /dev/ttyUSB0 --baud 19200 \
  --unit 3 --address 0 --count 10

Example output

Plugin name:    modbus/read-registers
Execution time: 0.08 s
Status:         pass

[HIGH] Modbus/TCP: unauthenticated read of Holding registers 0-9
  FC03: unit 1, 10 Holding registers at address 0.
  7/10 registers hold non-zero values.
  Evidence:
    [    0] 0x0064 =    100
    [    1] 0x01F4 =    500
    [    2] 0x0000 =      0
    [    3] 0x03E8 =   1000
    [    4] 0x0000 =      0
    [    5] 0x000A =     10
    [    6] 0x0032 =     50
    [    7] 0x0000 =      0
    [    8] 0x00C8 =    200
    [    9] 0x0001 =      1