modbus write-register

Writes one or more 16-bit values to Modbus holding registers without authentication. Two write modes are available:

ModeFunction codeFlag
Single registerFC06 — Write Single Register--value
Multiple registersFC16 — Write Multiple Registers--values

Values may be specified in decimal or 0x-prefixed hexadecimal.

Warning: Writing to holding registers can directly modify setpoints, configuration parameters or device state on industrial equipment.

Status

ResultMeaning
passWrite accepted by the device
failWrite rejected, parse error or connection failed

Severity classification

SeverityCondition
CriticalWrite succeeded (unauthenticated modification of device state)
InfoWrite failed, invalid value or connection failed

Usage

iottack modbus write-register --host <HOST> --value <VALUE> [OPTIONS]
iottack modbus write-register --host <HOST> --values <V1,V2,...> [OPTIONS]
iottack modbus write-register --serial <DEVICE> --value <VALUE> [OPTIONS]

Either --value or --values must be supplied.

Options

FlagShortDefaultDescription
--host <HOST>-H(required or –serial)Target hostname or IP for Modbus/TCP
--tcp-port <PORT>-502Modbus/TCP port
--serial <DEVICE>-s(required or –host)Serial device for Modbus RTU (e.g., /dev/ttyUSB0)
--baud <BAUD>-9600Baud rate for RTU serial
--unit <ID>-u1Modbus unit/slave ID (1-247)
--timeout-ms <MS>-t3000Timeout in milliseconds
--address <ADDR>-a0Target register address (0-65535)
--value <VALUE>-v-Single 16-bit value (decimal or 0xHEX) for FC06
--values <V1,V2,...>-V-Comma-separated values for FC16 multi-register write
--output <FILE>-o-Save result to a file
--format <FORMAT>-ftexttext or json
--verbose-v-Increase log verbosity

When both --value and --values are supplied, --values (FC16) takes precedence.

Examples

Write decimal value 100 to register 40:

iottack modbus write-register --host 192.168.1.100 \
  --address 40 --value 100

Write a hex value:

iottack modbus write-register --host 192.168.1.100 \
  --address 40 --value 0x0064

Write multiple registers starting at address 10:

iottack modbus write-register --host 192.168.1.100 \
  --address 10 --values 100,200,300,0xFF

Write over RTU serial, unit 2:

iottack modbus write-register --serial /dev/ttyUSB0 --unit 2 \
  --address 0 --value 1

Example output

Single register write (FC06):

Plugin name:    modbus/write-register
Execution time: 0.07 s
Status:         pass

[CRITICAL] Modbus/TCP: wrote register 40 = 0x0064 without authentication (FC06)
  Unit 1: register 40 written with value 100 (0x0064) without authentication.
  Evidence: "address=40 value=100 (0x0064)"

Multi-register write (FC16):

Plugin name:    modbus/write-register
Execution time: 0.09 s
Status:         pass

[CRITICAL] Modbus/TCP: wrote 4 registers at address 10 without authentication (FC16)
  Unit 1: 4 consecutive registers written starting at 10.
  Evidence:
    [   10] 0x0064 = 100
    [   11] 0x00C8 = 200
    [   12] 0x012C = 300
    [   13] 0x00FF = 255